CEIMSEL=CEIMSEL_0, CEIPEN=CEIPEN_0, CEIMEN=CEIMEN_0, CEIPSEL=CEIPSEL_0
Comparator Control Register 0
CEIPSEL | Channel input selected for the V+ terminal 0 (CEIPSEL_0): Channel 0 selected 1 (CEIPSEL_1): Channel 1 selected 2 (CEIPSEL_2): Channel 2 selected 3 (CEIPSEL_3): Channel 3 selected 4 (CEIPSEL_4): Channel 4 selected 5 (CEIPSEL_5): Channel 5 selected 6 (CEIPSEL_6): Channel 6 selected 7 (CEIPSEL_7): Channel 7 selected 8 (CEIPSEL_8): Channel 8 selected 9 (CEIPSEL_9): Channel 9 selected 10 (CEIPSEL_10): Channel 10 selected 11 (CEIPSEL_11): Channel 11 selected 12 (CEIPSEL_12): Channel 12 selected 13 (CEIPSEL_13): Channel 13 selected 14 (CEIPSEL_14): Channel 14 selected 15 (CEIPSEL_15): Channel 15 selected |
CEIPEN | Channel input enable for the V+ terminal 0 (CEIPEN_0): Selected analog input channel for V+ terminal is disabled 1 (CEIPEN_1): Selected analog input channel for V+ terminal is enabled |
CEIMSEL | Channel input selected for the - terminal 0 (CEIMSEL_0): Channel 0 selected 1 (CEIMSEL_1): Channel 1 selected 2 (CEIMSEL_2): Channel 2 selected 3 (CEIMSEL_3): Channel 3 selected 4 (CEIMSEL_4): Channel 4 selected 5 (CEIMSEL_5): Channel 5 selected 6 (CEIMSEL_6): Channel 6 selected 7 (CEIMSEL_7): Channel 7 selected 8 (CEIMSEL_8): Channel 8 selected 9 (CEIMSEL_9): Channel 9 selected 10 (CEIMSEL_10): Channel 10 selected 11 (CEIMSEL_11): Channel 11 selected 12 (CEIMSEL_12): Channel 12 selected 13 (CEIMSEL_13): Channel 13 selected 14 (CEIMSEL_14): Channel 14 selected 15 (CEIMSEL_15): Channel 15 selected |
CEIMEN | Channel input enable for the - terminal 0 (CEIMEN_0): Selected analog input channel for V- terminal is disabled 1 (CEIMEN_1): Selected analog input channel for V- terminal is enabled |